Genuine RRC2024 (6882607) Battery for MAQUET Getinge Servo Air Ventilator – Life‑Support Power You Can Trust
Exact replacement for MAQUET / Getinge part number: 6882607 (RRC2024 battery type). Compatible with Servo Air, Servo Air-v, and some Servo series ventilators. This includes Servo i and Servo u—check your device manual.
In an ICU, a long-term acute care hospital, or during patient transport, the MAQUET Getinge Servo Air serves more than as a ventilator. It’s a lifeline for patients with respiratory failure. When the battery fails, that lifeline is at risk.
The RRC2024 (6882607) is the factory-spec lithium-ion battery for the Servo Air platform. When new, it offers hours of backup power. This is enough for intra-hospital transport, power interruptions, or extended patient transfers. After a few years of daily charging, capacity fades. You might notice “low battery” warnings too soon. The device may shut down while moving or struggle to hold a charge.
You don’t need to pay MAQUET’s premium price ($600+). You can’t trust a $100 generic. It might swell, show error codes, or fail during transport. The RRC2024 battery offers medical-grade reliability, just like the original. Plus, it comes at a lower price.
Quick Specs – What You’re Getting
| Specification | Value |
|---|---|
| Part Number | 6882607 (RRC2024 battery type) |
| Compatible Devices | MAQUET Getinge Servo Air, Servo Air‑v (also Servo i, Servo u – check your original battery label) |
| Replace Part Numbers | RRC2024, 6882607 |
| Fits for Models | for MAQUET Getinge Servo Air Ventilator |
| Chemistry | Lithium‑ion (medical‑grade high‑rate cells) |
| Voltage | 14.4 V |
| Capacity | 6600mAh 95.0Wh |
| Safety Features | Over‑charge, over‑discharge, short‑circuit protection, temperature monitoring, cell balancing |
| Expected Runtime | Full original runtime – refer to Servo Air user manual (typically 2–4 hours depending on settings) |
| Compliance | IEC 60601‑1, UN38.3, CE, RoHS |
A healthy RRC2024 battery restores your Servo Air to its original backup runtime – enough for safe transport and uninterrupted respiratory support.
3 Signs Your Servo Air Ventilator Needs a New RRC2024 Battery
-
Reduced runtime – The device used to last through a typical transport (e.g., 2–3 hours). Now you see “low battery” warnings after only 60–90 minutes.
-
Error messages – The ventilator displays “battery error,” “low battery,” or “replace battery” even after a full charge cycle.
-
Physical swelling – The battery pack looks puffy, doesn’t slide in smoothly, or the case bulges. Replace immediately – a swollen lithium‑ion battery is a fire risk and can damage the device.
If your Servo Air battery is more than 2–3 years old or showing any of these signs, replace it now. Your patients depend on reliable backup power.
Why Choose Our Genuine RRC2024 Battery?
-
Authentic RRC2024 specification – Same medical‑grade cells and safety circuits as MAQUET original.
-
Fresh stock – Manufactured within the last 6 months. Date printed on label. No degraded shelf inventory.
-
Exact fit – Same dimensions, connector, and latch as OEM. Slides in and locks securely.
-
Full safety certifications – IEC 60601‑1 (medical electrical equipment), UN38.3 (air transport), CE, RoHS.
-
No error codes – Fully compatible with Servo Air, Servo Air‑v. No “battery not recognized” messages.
-
12‑month warranty – If it fails within 12 months, we send a free replacement.
-
Up to 60% less than MAQUET direct – You don’t need to pay the full medical OEM markup.
Your patients deserve reliability, not a gamble. Our genuine RRC2024 gives you OEM quality at a fair price.
Frequently Asked Questions (FAQ)
Q: Will this battery work with my MAQUET Servo Air or Servo Air‑v?
Yes. 6882607 (RRC2024) is the official battery for the Servo Air platform. Check your current battery label – if it says RRC2024 or 6882607, this is the direct replacement. Some Servo i and Servo u models also use the same battery – verify with your original part number.
Q: How do I replace the battery? Is it user‑serviceable?
Replacement should be performed by qualified biomedical engineering staff. The battery compartment is typically accessible with a latch or a few screws. Follow your Servo Air service manual. We provide installation instructions, but we strongly recommend professional replacement.
Q: How long does a full charge last after replacement?
Consult your Servo Air user manual for expected runtime. A new genuine battery restores original backup time – typically 2–4 hours depending on ventilator settings (FiO₂, tidal volume, breath rate, PEEP).
Q: Can I charge this battery in the original Servo Air charger/docking station?
Yes. It is fully compatible with MAQUET’s charging systems. No modifications needed.
Q: Is this battery safe for air transport (e.g., for hospital helicopters or fixed‑wing patient transport)?
Yes. It meets UN38.3 transportation safety standards. For medical use, always follow your hospital’s policies and aviation regulations for spare lithium batteries in life‑support equipment.
Q: What if my ventilator shows a battery error after installation?
First, ensure the battery is fully seated and the connector is secure. Charge the device for at least 2 hours. If the error persists, try a hard reset (refer to your ventilator’s technical manual). If none works, contact us for a replacement under warranty.
Q: Do you offer discounts for hospitals or biomedical departments buying multiple batteries?
Yes. For orders of 5+ batteries, contact us for a quote. We work with biomed departments, group purchasing organizations, and hospital supply chains.
Ready to Restore Your Servo Air’s Backup Power?
Don’t let a worn‑out or generic battery compromise respiratory support during transport or power interruption. This genuine RRC2024 (6882607) replacement gives you the same performance, safety, and longevity as the MAQUET original – at a price that makes replacing aging batteries a smart investment for your department.
| Battery Capacity | 6600mAh 95.0Wh |
| Voltage | 14.40V |
| Model No | RRC2024 |
| Warranty | 12 Months |
🔋 Lithium-Ion Battery Conditioning
For optimal electrochemical performance, new lithium-ion batteries should undergo 2–3 complete charge and discharge cycles before reaching full capacity.
This stabilization phase allows the internal cell chemistry to achieve balanced ion distribution, ensuring maximum runtime, stable voltage output, and extended cycle life.
After this initial conditioning period, no further full discharge cycles are required.
🛡 Premium Warranty Protection
- 12-Month Limited Manufacturer Warranty
- Up to 30-Day Return Guarantee (Policy Based)
- Replacement for defective or misrepresented items
- Dedicated customer service response within 24 hours
🚚 Professional Shipping Standards
- Orders placed Monday–Friday are processed within 1–2 business days. Orders placed on weekends are processed the following Monday.
- Tracking information appears in your order within 1–2 business days after dispatch.
- Transit time varies by region and logistics carrier
- Please verify your shipping address before order confirmation
- Address changes are not possible once shipment is dispatched
📌 Product-Specific Notice
📩 Customer Care Commitment
We are committed to delivering professional-grade battery solutions and responsive after-sales service. If you experience any issues, please contact our support team before leaving feedback.
⚕ Safety & Compatibility Notice — Medical Device Battery
This is a replacement battery for the compatible medical device model(s) listed above. It is not a finished medical device. The following guidelines apply:
| Who should install | Qualified biomedical technicians or authorized service personnel following the device manufacturer's service manual. AED/defibrillator batteries must comply with your facility's maintenance protocol. |
| After installation | Perform a full device self-test per the manufacturer's guidelines. Record the replacement date and result in the device maintenance log. |
| Emergency use | In a medical emergency, always contact local emergency services (911 in the US). This product does not replace emergency response services. |
| Liability | Accessories-Mall supplies replacement batteries for maintenance purposes. We are not liable for outcomes resulting from improper installation or failure to perform post-installation device testing. |
Not sure this battery fits? Send us your device model number — we'll confirm before you order.
Cao Chuanping
Power Systems Consultant · 8+ years in replacement battery sourcing & evaluation · View profile →
All batteries sold on accessories-mall.com are replacement parts. accessories-mall.com doesn't affiliate with any of the original manufacturers. Any registered trademarks or model names listed above are identified as purposes of showing compatibility only.