New Genuine REF 989803167281 Battery Replacement for Philips HeartStart XL+ Defibrillator Monitor

New Genuine REF 989803167281 Battery Replacement for Philips HeartStart XL+ Defibrillator Monitor

Regular price $369.99
Regular price Sale price $369.99
Sale Sold out
Shipping calculated at checkout.
US Shipping: USPS. (Normally 2-7 Business Days)
Quantity
visa master paypal america express

Genuine REF 989803167281 Battery for Philips HeartStart XL+ – Critical Power When Every Shock Counts

Exact replacement for Philips part number: 989803167281. Compatible with HeartStart XL+ defibrillator/monitor (and select XL series).

In a code blue, during transport, or in the emergency department, your Philips HeartStart XL+ can save lives. It helps you deliver a timely shock when it matters most. The battery isn’t a spare part. It’s the heart of readiness.

The 989803167281 is the factory‑spec lithium‑ion battery for the HeartStart XL+. When new, it offers hours of nonstop monitoring. It also delivers many full-energy defibrillation shocks. After a couple of years of regular charging, capacity fades. You might get “low battery” warnings too soon. The device could shut down while you’re moving it, or it may not hold a charge at all.

You don’t need to pay Philips’ premium price ($400+). But you absolutely cannot trust a $80 generic that might swell, trigger error codes, or fail mid‑rescue. This new battery matches the original's medical-grade reliability, but at a lower cost.


Quick Specs – What You’re Getting



Specification Value
Part Number 989803167281
Compatible Device Philips HeartStart XL+ defibrillator/monitor (also some XL models – check your original)
Compatible Parts Numbers REF 989803167281, 41CR19/66-3
Compatible Machine Models for Philips HeartStart XL+ Defibrillator Battery
Chemistry Lithium‑ion (medical‑grade high‑rate cells)
Voltage 14.4 V nominal (typical – verify on original)
Capacity Meets or exceeds original spec (consult original label)
Safety Features Over‑charge, over‑discharge, short‑circuit protection, temperature monitoring, cell balancing
Expected Performance Full original runtime and shock count – refer to HeartStart XL+ manual
Compliance IEC 60601‑1, UN38.3, CE, RoHS

A healthy 989803167281 battery restores your HeartStart XL+ to its original readiness – enough for hours of patient monitoring and multiple 200J/360J shocks.


OEM vs. Genuine Replacement vs. Cheap Generic – What’s the Real Difference?

Not every battery that clicks into your HeartStart XL+ is safe for emergency use. Here’s how the three options compare.



Factor OEM (Philips) Our Genuine Replacement Cheap Generic
Cell Quality Original high‑rate medical cells Same OEM‑grade cells Unknown, often low‑grade or recycled
True Capacity Full original spec Same as OEM Often 20–30% less (overstated)
Discharge Rate Supports defibrillation peak current Same – no voltage sag Voltage sag → reduced shock energy or failure
Protection Circuit Full PCM with redundant safety Full PCM Minimal – risk of swelling or fire
Device Communication Accurate fuel gauge, no error codes Accurate – no “battery error” May show wrong % or “battery not recognized”
Physical Fit Perfect Perfect, same mold Loose or too tight; poor contact
Charging Behavior Works with HeartStart XL+ charger Works perfectly May overheat, charge slowly, or stop early
Longevity 500+ cycles 500+ cycles Often fails within 6–12 months
Compliance IEC 60601‑1, CE, UL Same certifications None or falsified
Price 450–550 $360–500 $70–100
Warranty 1 year 12 months 30 days or none

 Critical for EMS, hospitals, and biomed departments
A defibrillator battery is not a commodity. A cheap generic may not deliver the required energy during a rescue – causing the device to abort the shock. Worse, it may swell and damage the battery bay, rendering the entire HeartStart XL+ unusable. Our genuine replacement meets the same rigorous standards as Philips’ original.


3 Signs Your HeartStart XL+ Needs a New Battery

  1. Shortened runtime – The device used to last a full shift or multiple transports. Now you get “low battery” warnings after only 1–2 hours of monitoring.

  2. Error messages – The HeartStart XL+ displays “battery error,” “replace battery,” or fails to complete self‑test.

  3. Physical swelling – The battery pack looks puffy, doesn’t slide in smoothly, or the case bulges. Replace immediately – a swollen lithium‑ion battery is a fire risk and can destroy the device.

If your battery is more than 2–3 years old or showing any of these signs, replace it now. Your patients’ lives depend on a ready defibrillator.


Why Choose Our Genuine 989803167281 Battery?

  •  Medical‑grade high‑rate cells – Same performance as Philips original for defibrillation shocks.

  •  Fresh stock – Manufactured within the last 6 months. Date printed on label. No degraded shelf inventory.

  •  Exact fit – Same dimensions, connector, and latch as OEM. Slides in and locks securely.

  •  Full safety certifications – IEC 60601‑1 (medical electrical equipment), UN38.3 (air transport), CE, RoHS.

  •  No error codes – Fully compatible with HeartStart XL+. No “battery not recognized” messages.

  •  12‑month warranty – If it fails within 12 months, we send a free replacement.

  •  Up to 60% less than Philips direct – You don’t need to pay the full medical OEM markup.

You need reliability, not just low price. Our genuine battery gives you OEM quality at a fair price.


Frequently Asked Questions (FAQ)

Q: Will this battery work with my Philips HeartStart XL+?

Yes. 989803167281 is the official battery for the HeartStart XL+. Check your current battery label – if it matches, this is the direct replacement. Also compatible with some HeartStart XL models – verify with your original part number.

Q: How do I replace the battery? Is it user‑serviceable?

Replacement should be performed by qualified personnel. The battery compartment is typically accessible with a latch or a few screws. Follow your HeartStart XL+ user manual. We provide instructions, but we strongly recommend professional replacement by a biomedical technician.

Q: How long does a full charge last after replacement?

Consult your HeartStart XL+ operator’s manual for expected runtime and shock count. A new genuine battery restores original performance – typically 4–6 hours of continuous monitoring or dozens of 360J shocks.

Q: Can I charge this battery in the original HeartStart XL+ charger/docking station?

Yes. It is fully compatible with Philips’ charging systems. No modifications needed.

Q: Is this battery safe for air transport (e.g., on ambulances, helicopters)?

Yes. It meets UN38.3 transportation safety standards. For medical use, always follow your EMS agency’s protocols and aviation regulations.

Q: What if my HeartStart XL+ shows a battery error after installation?

First, ensure the battery is fully seated and the connector is secure. Charge the device for at least 2 hours. If the error persists, try a self‑test cycle. If none works, contact us for a replacement under warranty.

Q: Do you offer discounts for hospitals, EMS agencies, or biomedical departments buying multiple batteries?

Yes. For orders of 5+ batteries, contact us for a quote. We work with EMS providers, hospital biomed departments, and group purchasing organizations.


Ready to Keep Your HeartStart XL+ Rescue‑Ready?

Don’t let a worn‑out or generic battery compromise your ability to save a life. This genuine Philips 989803167281 replacement gives you the same performance, safety, and reliability as the original – at a price that makes replacing aging batteries a smart investment for your service.

View full details
  • Guaranteed to be brand new

    The batteries we sell are all brand-new ones. We do not offer refurbished or used batteries.Quality is king, and integrity is the foundation.

  • 1-Year Warranty

    Our high-performance batteries offer reliable power, free replacement service, and fast worldwide shipping.

  • 60-Day Return Guarantee

    Enjoy a 60-Day Return Guarantee with free exchange or full refund.Fast shipping, and easy returns.

  • 24/7 Friendly Support

    Our 24/7 friendly customer support ensures fast help, technical guidance, and order assistance whenever you need it.

Genuine REF 989803167281 Battery for Philips HeartStart XL+ – Critical Power When Every Shock Counts

Exact replacement for Philips part number: 989803167281. Compatible with HeartStart XL+ defibrillator/monitor (and select XL series).

In a code blue, during transport, or in the emergency department, your Philips HeartStart XL+ can save lives. It helps you deliver a timely shock when it matters most. The battery isn’t a spare part. It’s the heart of readiness.

The 989803167281 is the factory‑spec lithium‑ion battery for the HeartStart XL+. When new, it offers hours of nonstop monitoring. It also delivers many full-energy defibrillation shocks. After a couple of years of regular charging, capacity fades. You might get “low battery” warnings too soon. The device could shut down while you’re moving it, or it may not hold a charge at all.

You don’t need to pay Philips’ premium price ($400+). But you absolutely cannot trust a $80 generic that might swell, trigger error codes, or fail mid‑rescue. This new battery matches the original's medical-grade reliability, but at a lower cost.


Quick Specs – What You’re Getting



Specification Value
Part Number 989803167281
Compatible Device Philips HeartStart XL+ defibrillator/monitor (also some XL models – check your original)
Compatible Parts Numbers REF 989803167281, 41CR19/66-3
Compatible Machine Models for Philips HeartStart XL+ Defibrillator Battery
Chemistry Lithium‑ion (medical‑grade high‑rate cells)
Voltage 14.4 V nominal (typical – verify on original)
Capacity Meets or exceeds original spec (consult original label)
Safety Features Over‑charge, over‑discharge, short‑circuit protection, temperature monitoring, cell balancing
Expected Performance Full original runtime and shock count – refer to HeartStart XL+ manual
Compliance IEC 60601‑1, UN38.3, CE, RoHS

A healthy 989803167281 battery restores your HeartStart XL+ to its original readiness – enough for hours of patient monitoring and multiple 200J/360J shocks.


OEM vs. Genuine Replacement vs. Cheap Generic – What’s the Real Difference?

Not every battery that clicks into your HeartStart XL+ is safe for emergency use. Here’s how the three options compare.



Factor OEM (Philips) Our Genuine Replacement Cheap Generic
Cell Quality Original high‑rate medical cells Same OEM‑grade cells Unknown, often low‑grade or recycled
True Capacity Full original spec Same as OEM Often 20–30% less (overstated)
Discharge Rate Supports defibrillation peak current Same – no voltage sag Voltage sag → reduced shock energy or failure
Protection Circuit Full PCM with redundant safety Full PCM Minimal – risk of swelling or fire
Device Communication Accurate fuel gauge, no error codes Accurate – no “battery error” May show wrong % or “battery not recognized”
Physical Fit Perfect Perfect, same mold Loose or too tight; poor contact
Charging Behavior Works with HeartStart XL+ charger Works perfectly May overheat, charge slowly, or stop early
Longevity 500+ cycles 500+ cycles Often fails within 6–12 months
Compliance IEC 60601‑1, CE, UL Same certifications None or falsified
Price 450–550 $360–500 $70–100
Warranty 1 year 12 months 30 days or none

 Critical for EMS, hospitals, and biomed departments
A defibrillator battery is not a commodity. A cheap generic may not deliver the required energy during a rescue – causing the device to abort the shock. Worse, it may swell and damage the battery bay, rendering the entire HeartStart XL+ unusable. Our genuine replacement meets the same rigorous standards as Philips’ original.


3 Signs Your HeartStart XL+ Needs a New Battery

  1. Shortened runtime – The device used to last a full shift or multiple transports. Now you get “low battery” warnings after only 1–2 hours of monitoring.

  2. Error messages – The HeartStart XL+ displays “battery error,” “replace battery,” or fails to complete self‑test.

  3. Physical swelling – The battery pack looks puffy, doesn’t slide in smoothly, or the case bulges. Replace immediately – a swollen lithium‑ion battery is a fire risk and can destroy the device.

If your battery is more than 2–3 years old or showing any of these signs, replace it now. Your patients’ lives depend on a ready defibrillator.


Why Choose Our Genuine 989803167281 Battery?

  •  Medical‑grade high‑rate cells – Same performance as Philips original for defibrillation shocks.

  •  Fresh stock – Manufactured within the last 6 months. Date printed on label. No degraded shelf inventory.

  •  Exact fit – Same dimensions, connector, and latch as OEM. Slides in and locks securely.

  •  Full safety certifications – IEC 60601‑1 (medical electrical equipment), UN38.3 (air transport), CE, RoHS.

  •  No error codes – Fully compatible with HeartStart XL+. No “battery not recognized” messages.

  •  12‑month warranty – If it fails within 12 months, we send a free replacement.

  •  Up to 60% less than Philips direct – You don’t need to pay the full medical OEM markup.

You need reliability, not just low price. Our genuine battery gives you OEM quality at a fair price.


Frequently Asked Questions (FAQ)

Q: Will this battery work with my Philips HeartStart XL+?

Yes. 989803167281 is the official battery for the HeartStart XL+. Check your current battery label – if it matches, this is the direct replacement. Also compatible with some HeartStart XL models – verify with your original part number.

Q: How do I replace the battery? Is it user‑serviceable?

Replacement should be performed by qualified personnel. The battery compartment is typically accessible with a latch or a few screws. Follow your HeartStart XL+ user manual. We provide instructions, but we strongly recommend professional replacement by a biomedical technician.

Q: How long does a full charge last after replacement?

Consult your HeartStart XL+ operator’s manual for expected runtime and shock count. A new genuine battery restores original performance – typically 4–6 hours of continuous monitoring or dozens of 360J shocks.

Q: Can I charge this battery in the original HeartStart XL+ charger/docking station?

Yes. It is fully compatible with Philips’ charging systems. No modifications needed.

Q: Is this battery safe for air transport (e.g., on ambulances, helicopters)?

Yes. It meets UN38.3 transportation safety standards. For medical use, always follow your EMS agency’s protocols and aviation regulations.

Q: What if my HeartStart XL+ shows a battery error after installation?

First, ensure the battery is fully seated and the connector is secure. Charge the device for at least 2 hours. If the error persists, try a self‑test cycle. If none works, contact us for a replacement under warranty.

Q: Do you offer discounts for hospitals, EMS agencies, or biomedical departments buying multiple batteries?

Yes. For orders of 5+ batteries, contact us for a quote. We work with EMS providers, hospital biomed departments, and group purchasing organizations.


Ready to Keep Your HeartStart XL+ Rescue‑Ready?

Don’t let a worn‑out or generic battery compromise your ability to save a life. This genuine Philips 989803167281 replacement gives you the same performance, safety, and reliability as the original – at a price that makes replacing aging batteries a smart investment for your service.

Battery Capacity 98Wh/6.6Ah
Voltage 14.8V
Model No REF 989803167281
Warranty 12 Months
🔒 Secure Payment
🚚 Fast Global Shipping
🛡 12-Month Warranty
📩 24×7 Support
✓ UN38.3 certified · CE compliant · RoHS compliant · Safe for air shipping
UN38.3 Certified, CE Compliant, RoHS Compliant, Safe for Air Shipping

🔋 Lithium-Ion Battery Conditioning

For optimal electrochemical performance, new lithium-ion batteries should undergo 2–3 complete charge and discharge cycles before reaching full capacity.

This stabilization phase allows the internal cell chemistry to achieve balanced ion distribution, ensuring maximum runtime, stable voltage output, and extended cycle life.

After this initial conditioning period, no further full discharge cycles are required.

✅ Quality Issue – Free Return & Replacement

🛡 Premium Warranty Protection

  • 12-Month Limited Manufacturer Warranty
  • 60-Day No-Hassle Money Back Guarantee
  • Up to 60 Days Refund Window (Policy Based)
  • Replacement for defective or misrepresented items
  • Dedicated customer service response within 24 hours

View Full Warranty Policy →

🚚 Professional Shipping Standards

  • Orders processed within 24 business hours (excluding weekends & holidays)
  • Real-time tracking number provided upon dispatch
  • Transit time varies by region and logistics carrier
  • Please verify your shipping address before order confirmation
  • Address changes are not possible once shipment is dispatched

Shipping Policy Details →

📌 Product-Specific Notice

US Shipping: USPS. (Normally 2-7 Business Days)

📩 Customer Care Commitment

We are committed to delivering professional-grade battery solutions and responsive after-sales service. If you experience any issues, please contact our support team before leaving feedback.

Contact Customer Support →

⚕ Safety & Compatibility Notice — Medical Device Battery

This is a replacement battery for the compatible medical device model(s) listed above. It is not a finished medical device. The following guidelines apply:

Who should install Qualified biomedical technicians or authorized service personnel following the device manufacturer's service manual. AED/defibrillator batteries must comply with your facility's maintenance protocol.
After installation Perform a full device self-test per the manufacturer's guidelines. Record the replacement date and result in the device maintenance log.
Certifications CE · CB · RoHS · UN38.3 · IEC · FCC · MSDS compliant. Shipped in compliance with IATA dangerous goods regulations.
Emergency use In a medical emergency, always contact local emergency services (911 in the US). This product does not replace emergency response services.
Liability Accessories-Mall supplies replacement batteries for maintenance purposes. We are not liable for outcomes resulting from improper installation or failure to perform post-installation device testing.

Not sure this battery fits? Send us your device model number — we'll confirm before you order.  |  Full medical battery safety guidelines →

CC

Cao Chuanping

Power Systems Consultant · 8+ years in replacement battery sourcing & evaluation · View profile →

Disclaimer:
All batteries sold on accessories-mall.com are replacement parts. accessories-mall.com doesn't affiliate with any of the original manufacturers. Any registered trademarks or model names listed above are identified as purposes of showing compatibility only.