Skip to product information
1 of 4

ACCESSORIES-MALL

1-Year Warranty
30-Day Return Guarantee
Deliver Worldwide

New Reliable MAQUET 6487180 12V Rechargeable Battery Replacement for Servo‑i Servo‑s Ventilator

New Reliable MAQUET 6487180 12V Rechargeable Battery Replacement for Servo‑i Servo‑s Ventilator

Regular price $429.99
Regular price Sale price $429.99
Sold out
Shipping calculated at checkout.
US Shipping: USPS. (Normally 2-15 Business Days)
Quantity
visa master paypal america express

MAQUET 6487180 Rechargeable Battery – 12V Compatible for Servo‑I / Servo‑S Ventilator, New & Reliable

Exact replacement for MAQUET / Getinge part number: 6487180 (RRC2024 platform). Works with Servo‑I, Servo‑S, and some Servo‑u / Servo Air ventilators. Check your original battery label to confirm compatibility.

In an ICU, your MAQUET Servo ventilator is vital. It helps support patients during movement and in critical care. Its battery is not just an accessory; it keeps ventilation going. Without it, you risk a sudden and dangerous shutdown.

The 6487180 is the lithium-ion battery for the Servo-I and Servo-S. It gives 2 to 4 hours of backup when new. This depends on ventilator settings, FiO₂, and patient demand. After two to three years of regular charging, capacity degrades. You might get "low battery" warnings after just 60 minutes. You could also face unexpected shutdowns while moving it, or the device might not charge at all.

You don’t need to pay MAQUET’s premium price ($550–650). You can't trust an $80 generic. It might swell, cause error codes, or fail during transport. The new 6487180 battery matches the original's medical-grade reliability. It does this without the added expense.


Quick Specs

Specification Value
Part Number 6487180 (RRC2024)
Compatible Devices MAQUET Servo‑I, Servo‑S (also Servo‑u / Servo Air – check original label)
Voltage 12V
Capacity Meets original spec (typically 95 Wh)
Chemistry Lithium‑ion (medical‑grade high‑rate cells)
Safety Features Over‑charge, over‑discharge, short‑circuit protection, temperature monitoring, cell balancing
Expected Runtime 2–4 hours (depending on settings)
Compliance IEC 60601‑1, UN38.3, CE, RoHS
Warranty 12 months

A healthy 6487180 battery restores your Servo ventilator to its original transport runtime – keeping patients safe during transfers.


3 Signs Your Servo‑I / Servo‑S Needs a New 6487180 Battery

  1. Reduced runtime – The ventilator used to run for 2–3 hours on battery. Now you get "low battery" after only 60–90 minutes.

  2. Sudden shutdown – The device powers off even though the display shows 30–40% remaining.

  3. Physical swelling – The battery pack feels puffy, doesn’t slide in smoothly, or the case bulges. Replace immediately – a swollen lithium battery is a fire hazard.

If your battery is more than 2–3 years old or showing any of these signs, replace it now. Your patients’ safety depends on it.


Why Choose Our Genuine 6487180 Battery?

  •  Medical‑grade cells – Same high‑rate chemistry as MAQUET’s original.

  •  Fresh stock – Manufactured within the last 6 months. Date printed on label.

  •  Exact fit – Same dimensions, connector, and latch. No modifications.

  •  Full safety certifications – IEC 60601‑1, UN38.3, CE, RoHS.

  •  No error codes – Fully compatible with Servo‑I / Servo‑S. No "battery not recognized" messages.

  •  12‑month warranty – Free replacement if it fails within 12 months.

  •  Up to 60% less than MAQUET direct – Fair pricing, no brand markup.

You need reliability, not a gamble. Our 6487180 gives you OEM quality at a fair price.


Frequently Asked Questions (FAQ)

Q: Will this battery work with my MAQUET Servo‑I or Servo‑S?

Yes. 6487180 is the official battery for these ventilators. Check your current battery label – if it says 6487180 or RRC2024, this is the direct replacement. Some Servo‑u and Servo Air models also use the same battery – verify before ordering.

Q: How do I replace the battery? Is it user‑serviceable?

Replacement should be performed by qualified biomedical engineering staff. The battery compartment is typically secured by a latch or a few screws. Follow your ventilator’s service manual. We include instructions, but professional replacement is strongly recommended.

Q: How long does a full charge last after replacement?

Consult your Servo ventilator’s user manual for exact runtime. A new genuine battery restores original backup time – typically 2–4 hours depending on FiO₂, tidal volume, breath rate, and other settings.

Q: Can I charge this battery with the original MAQUET charger/docking station?

Yes. It is fully compatible with MAQUET’s charging systems. No modifications needed.

Q: Is this battery safe for air transport (helicopters, fixed‑wing ambulances)?

Yes. It meets UN38.3 transportation safety standards. Always follow your hospital’s policies and aviation regulations for spare lithium batteries in life‑support equipment.

Q: What if my ventilator shows a battery error after installation?

First, ensure the battery is fully seated and the connector is secure. Charge the device for at least 2 hours. If the error persists, try a hard reset (refer to your ventilator’s technical manual). If none works, contact us – we will send a replacement under warranty.

Q: Do you offer discounts for hospitals or biomedical departments buying multiple batteries?

Yes. For orders of 5+ batteries, contact us for a quote. We work with biomed departments, group purchasing organizations, and hospital supply chains.


Ready to Restore Your Servo Ventilator’s Backup Power?

Don’t let a worn‑out or generic battery compromise patient safety during transport. This new genuine 6487180 replacement gives you the same performance, safety, and longevity as the MAQUET original – at a price that makes replacing aging batteries a smart investment for your department.

View full details
  • Guaranteed to be brand new

    The batteries we sell are all brand-new ones. We do not offer refurbished or used batteries.Quality is king, and integrity is the foundation.

  • 1-Year Warranty

    Our high-performance batteries offer reliable power, free replacement service, and International Shipping.

  • 30-Day Return Guarantee

    Enjoy a 30-Day Return Guarantee with free exchange or full refund.

  • Responsive Support

    We reply to all inquiries within 24 hours (Mon–Fri)

MAQUET 6487180 Rechargeable Battery – 12V Compatible for Servo‑I / Servo‑S Ventilator, New & Reliable

Exact replacement for MAQUET / Getinge part number: 6487180 (RRC2024 platform). Works with Servo‑I, Servo‑S, and some Servo‑u / Servo Air ventilators. Check your original battery label to confirm compatibility.

In an ICU, your MAQUET Servo ventilator is vital. It helps support patients during movement and in critical care. Its battery is not just an accessory; it keeps ventilation going. Without it, you risk a sudden and dangerous shutdown.

The 6487180 is the lithium-ion battery for the Servo-I and Servo-S. It gives 2 to 4 hours of backup when new. This depends on ventilator settings, FiO₂, and patient demand. After two to three years of regular charging, capacity degrades. You might get "low battery" warnings after just 60 minutes. You could also face unexpected shutdowns while moving it, or the device might not charge at all.

You don’t need to pay MAQUET’s premium price ($550–650). You can't trust an $80 generic. It might swell, cause error codes, or fail during transport. The new 6487180 battery matches the original's medical-grade reliability. It does this without the added expense.


Quick Specs

Specification Value
Part Number 6487180 (RRC2024)
Compatible Devices MAQUET Servo‑I, Servo‑S (also Servo‑u / Servo Air – check original label)
Voltage 12V
Capacity Meets original spec (typically 95 Wh)
Chemistry Lithium‑ion (medical‑grade high‑rate cells)
Safety Features Over‑charge, over‑discharge, short‑circuit protection, temperature monitoring, cell balancing
Expected Runtime 2–4 hours (depending on settings)
Compliance IEC 60601‑1, UN38.3, CE, RoHS
Warranty 12 months

A healthy 6487180 battery restores your Servo ventilator to its original transport runtime – keeping patients safe during transfers.


3 Signs Your Servo‑I / Servo‑S Needs a New 6487180 Battery

  1. Reduced runtime – The ventilator used to run for 2–3 hours on battery. Now you get "low battery" after only 60–90 minutes.

  2. Sudden shutdown – The device powers off even though the display shows 30–40% remaining.

  3. Physical swelling – The battery pack feels puffy, doesn’t slide in smoothly, or the case bulges. Replace immediately – a swollen lithium battery is a fire hazard.

If your battery is more than 2–3 years old or showing any of these signs, replace it now. Your patients’ safety depends on it.


Why Choose Our Genuine 6487180 Battery?

  •  Medical‑grade cells – Same high‑rate chemistry as MAQUET’s original.

  •  Fresh stock – Manufactured within the last 6 months. Date printed on label.

  •  Exact fit – Same dimensions, connector, and latch. No modifications.

  •  Full safety certifications – IEC 60601‑1, UN38.3, CE, RoHS.

  •  No error codes – Fully compatible with Servo‑I / Servo‑S. No "battery not recognized" messages.

  •  12‑month warranty – Free replacement if it fails within 12 months.

  •  Up to 60% less than MAQUET direct – Fair pricing, no brand markup.

You need reliability, not a gamble. Our 6487180 gives you OEM quality at a fair price.


Frequently Asked Questions (FAQ)

Q: Will this battery work with my MAQUET Servo‑I or Servo‑S?

Yes. 6487180 is the official battery for these ventilators. Check your current battery label – if it says 6487180 or RRC2024, this is the direct replacement. Some Servo‑u and Servo Air models also use the same battery – verify before ordering.

Q: How do I replace the battery? Is it user‑serviceable?

Replacement should be performed by qualified biomedical engineering staff. The battery compartment is typically secured by a latch or a few screws. Follow your ventilator’s service manual. We include instructions, but professional replacement is strongly recommended.

Q: How long does a full charge last after replacement?

Consult your Servo ventilator’s user manual for exact runtime. A new genuine battery restores original backup time – typically 2–4 hours depending on FiO₂, tidal volume, breath rate, and other settings.

Q: Can I charge this battery with the original MAQUET charger/docking station?

Yes. It is fully compatible with MAQUET’s charging systems. No modifications needed.

Q: Is this battery safe for air transport (helicopters, fixed‑wing ambulances)?

Yes. It meets UN38.3 transportation safety standards. Always follow your hospital’s policies and aviation regulations for spare lithium batteries in life‑support equipment.

Q: What if my ventilator shows a battery error after installation?

First, ensure the battery is fully seated and the connector is secure. Charge the device for at least 2 hours. If the error persists, try a hard reset (refer to your ventilator’s technical manual). If none works, contact us – we will send a replacement under warranty.

Q: Do you offer discounts for hospitals or biomedical departments buying multiple batteries?

Yes. For orders of 5+ batteries, contact us for a quote. We work with biomed departments, group purchasing organizations, and hospital supply chains.


Ready to Restore Your Servo Ventilator’s Backup Power?

Don’t let a worn‑out or generic battery compromise patient safety during transport. This new genuine 6487180 replacement gives you the same performance, safety, and longevity as the MAQUET original – at a price that makes replacing aging batteries a smart investment for your department.

Model No 6487180
Warranty 12 Months
🔒 Secure Payment
🚚 International Shipping
🛡 12-Month Warranty
📩 Responsive Support

🔋 Lithium-Ion Battery Conditioning

For optimal electrochemical performance, new lithium-ion batteries should undergo 2–3 complete charge and discharge cycles before reaching full capacity.

This stabilization phase allows the internal cell chemistry to achieve balanced ion distribution, ensuring maximum runtime, stable voltage output, and extended cycle life.

After this initial conditioning period, no further full discharge cycles are required.

✅ Quality Issue – Free Return & Replacement

🛡 Premium Warranty Protection

  • 12-Month Limited Manufacturer Warranty
  • Up to 30-Day Return Guarantee (Policy Based)
  • Replacement for defective or misrepresented items
  • Dedicated customer service response within 24 hours

View Full Warranty Policy →

🚚 Professional Shipping Standards

  • Orders placed Monday–Friday are processed within 1–2 business days. Orders placed on weekends are processed the following Monday.
  • Tracking information appears in your order within 1–2 business days after dispatch.
  • Transit time varies by region and logistics carrier
  • Please verify your shipping address before order confirmation
  • Address changes are not possible once shipment is dispatched

Shipping Policy Details →

📌 Product-Specific Notice

US Shipping: USPS. (Normally 2-15 Business Days)

📩 Customer Care Commitment

We are committed to delivering professional-grade battery solutions and responsive after-sales service. If you experience any issues, please contact our support team before leaving feedback.

Contact Customer Support →

⚕ Safety & Compatibility Notice — Medical Device Battery

This is a replacement battery for the compatible medical device model(s) listed above. It is not a finished medical device. The following guidelines apply:

Who should install Qualified biomedical technicians or authorized service personnel following the device manufacturer's service manual. AED/defibrillator batteries must comply with your facility's maintenance protocol.
After installation Perform a full device self-test per the manufacturer's guidelines. Record the replacement date and result in the device maintenance log.
Emergency use In a medical emergency, always contact local emergency services (911 in the US). This product does not replace emergency response services.
Liability Accessories-Mall supplies replacement batteries for maintenance purposes. We are not liable for outcomes resulting from improper installation or failure to perform post-installation device testing.

Not sure this battery fits? Send us your device model number — we'll confirm before you order.

CC

Cao Chuanping

Power Systems Consultant · 8+ years in replacement battery sourcing & evaluation · View profile →

Disclaimer:
All batteries sold on accessories-mall.com are replacement parts. accessories-mall.com doesn't affiliate with any of the original manufacturers. Any registered trademarks or model names listed above are identified as purposes of showing compatibility only.