REF 989803206461 Battery Replacement for Philips Defibrillator 41NR19/66-2

REF 989803206461 Battery Replacement for Philips Defibrillator 41NR19/66-2

Regular price $419.99
Regular price Sale price $419.99
Sold out
Shipping calculated at checkout.
US Shipping: USPS. (Normally 2-15 Business Days)
Quantity
visa master paypal america express

New Genuine REF 989803206461 Battery for Philips Defibrillator 41NR19/66-2

Ensure dependable power performance with this genuine REF 989803206461 battery designed for compatible Philips defibrillator systems. Manufactured with premium Grade A lithium-ion cells, this high-quality replacement battery delivers stable power output, reliable operation, and long-lasting durability for professional equipment applications.

Engineered to meet OEM specifications, the REF 989803206461 battery provides seamless compatibility and consistent performance. Whether replacing an existing battery or maintaining backup inventory, this genuine battery offers a trusted solution with excellent reliability and value.

Built for dependable charging efficiency and extended service life, this Philips defibrillator battery is thoroughly tested to help ensure quality, safety, and performance.

Compatible Equipment

  • Compatible Philips Defibrillator Systems
  • Compatible with REF 989803206461 Battery
  • Compatible with 41NR19/66-2 Battery Pack
Replace Part Numbers:
REF 989803206461, 41NR19/66-2

The Clinical Mandate for Authentic OEM Components

For hospital procurement officers and clinical engineering (biomed) departments, the decision to source original equipment manufacturer (OEM) parts goes far beyond basic performance—it is a matter of strict regulatory compliance and liability mitigation.

Integrating aftermarket or unverified third-party batteries into life-support and resuscitation devices introduces catastrophic risks, including failure to charge capacitors, sudden power loss during transport, and motherboard damage.

By equipping your fleet with this genuine Philips battery, your facility guarantees:

  • Rapid Therapy Delivery: Designed specifically to handle the massive, instantaneous current draw required to charge a defibrillator to its maximum joule setting in seconds.

  • Flawless BMS Communication: The battery's integrated smart microchip interfaces perfectly with the Efficia DFM100’s internal Battery Management System, providing highly accurate remaining-runtime telemetry and preventing false low-battery alarms.

  • Uncompromised Warranty & Compliance: Utilizing authentic Philips components ensures adherence to Joint Commission equipment standards and preserves the manufacturer's liability and warranty frameworks.

Advanced Cell Chemistry & Performance Capability

The internal 41NR19/66-2 lithium-ion cell architecture is specifically calibrated for the dual demands of modern defibrillators. It provides the sustained, low-draw energy needed for hours of continuous non-invasive pacing, 12-lead ECG, SpO2, and NIBP monitoring, while keeping highly dense reserve power immediately available for rapid, biphasic shock delivery.

Verified Hardware Compatibility & Specifications

This unit is a brand-new, factory-sealed replacement part, verified for complete physical and electronic integration with specific Philips medical devices.

  • Manufacturer: Philips Healthcare
  • OEM Reference Number: REF 989803206461
  • Cell Designation Model: 41NR19/66-2
  • Battery Chemistry: Rechargeable Smart Lithium-Ion
  • Supported Device: Philips Efficia DFM100 Monitor/Defibrillator
  • Voltage: 14.68V
  • Capacity: 79.2Wh/5.4Ah
  • Cell Details: Premium Grade A Lithium-Ion Cells
  • Condition: Genuine New
  • Warranty: 12 Monthst

Biomedical Maintenance Directives

To secure the maximum operational lifespan of this lithium-ion module and ensure constant emergency readiness, clinical engineering technicians should implement the following protocols:

  • Continuous Float Charging: Defibrillators are emergency devices. When the Efficia DFM100 is stationed on a crash cart or not in active clinical use, it must remain continuously plugged into a verified AC power source to maintain the battery at a 100% state of charge.

  • Capacity Calibration: Upon initial installation, connect the device to AC power and allow the new battery to reach full capacity before deploying the defibrillator into active patient care.

  • Proactive Replacement Intervals: Despite showing adequate charge levels on the device display, the internal chemical impedance of defibrillator batteries degrades over time due to the extreme nature of their potential discharge cycles. Adhere strictly to the preventative maintenance (PM) replacement timeline outlined in your Philips service manual to avoid unexpected cell collapse during an emergency.

Why Choose This Philips Defibrillator Battery?

The genuine REF 989803206461 battery is designed to deliver consistent power performance and dependable reliability for compatible Philips equipment. Using high-quality lithium-ion cells, this battery provides stable energy output, efficient charging performance, and extended operational life.

Compared with lower-quality aftermarket alternatives, this OEM-quality replacement battery offers better compatibility, enhanced safety protection, and long-term durability, making it a smart investment for maintaining equipment readiness and dependable performance.

View full details
  • Guaranteed to be brand new

    The batteries we sell are all brand-new ones. We do not offer refurbished or used batteries.Quality is king, and integrity is the foundation.

  • 1-Year Warranty

    Our high-performance batteries offer reliable power, free replacement service, and International Shipping.

  • 30-Day Return Guarantee

    Enjoy a 30-Day Return Guarantee with free exchange or full refund.

  • Responsive Support

    We reply to all inquiries within 24 hours (Mon–Fri)


New Genuine REF 989803206461 Battery for Philips Defibrillator 41NR19/66-2

Ensure dependable power performance with this genuine REF 989803206461 battery designed for compatible Philips defibrillator systems. Manufactured with premium Grade A lithium-ion cells, this high-quality replacement battery delivers stable power output, reliable operation, and long-lasting durability for professional equipment applications.

Engineered to meet OEM specifications, the REF 989803206461 battery provides seamless compatibility and consistent performance. Whether replacing an existing battery or maintaining backup inventory, this genuine battery offers a trusted solution with excellent reliability and value.

Built for dependable charging efficiency and extended service life, this Philips defibrillator battery is thoroughly tested to help ensure quality, safety, and performance.

Compatible Equipment

  • Compatible Philips Defibrillator Systems
  • Compatible with REF 989803206461 Battery
  • Compatible with 41NR19/66-2 Battery Pack
Replace Part Numbers:
REF 989803206461, 41NR19/66-2

The Clinical Mandate for Authentic OEM Components

For hospital procurement officers and clinical engineering (biomed) departments, the decision to source original equipment manufacturer (OEM) parts goes far beyond basic performance—it is a matter of strict regulatory compliance and liability mitigation.

Integrating aftermarket or unverified third-party batteries into life-support and resuscitation devices introduces catastrophic risks, including failure to charge capacitors, sudden power loss during transport, and motherboard damage.

By equipping your fleet with this genuine Philips battery, your facility guarantees:

  • Rapid Therapy Delivery: Designed specifically to handle the massive, instantaneous current draw required to charge a defibrillator to its maximum joule setting in seconds.

  • Flawless BMS Communication: The battery's integrated smart microchip interfaces perfectly with the Efficia DFM100’s internal Battery Management System, providing highly accurate remaining-runtime telemetry and preventing false low-battery alarms.

  • Uncompromised Warranty & Compliance: Utilizing authentic Philips components ensures adherence to Joint Commission equipment standards and preserves the manufacturer's liability and warranty frameworks.

Advanced Cell Chemistry & Performance Capability

The internal 41NR19/66-2 lithium-ion cell architecture is specifically calibrated for the dual demands of modern defibrillators. It provides the sustained, low-draw energy needed for hours of continuous non-invasive pacing, 12-lead ECG, SpO2, and NIBP monitoring, while keeping highly dense reserve power immediately available for rapid, biphasic shock delivery.

Verified Hardware Compatibility & Specifications

This unit is a brand-new, factory-sealed replacement part, verified for complete physical and electronic integration with specific Philips medical devices.

  • Manufacturer: Philips Healthcare
  • OEM Reference Number: REF 989803206461
  • Cell Designation Model: 41NR19/66-2
  • Battery Chemistry: Rechargeable Smart Lithium-Ion
  • Supported Device: Philips Efficia DFM100 Monitor/Defibrillator
  • Voltage: 14.68V
  • Capacity: 79.2Wh/5.4Ah
  • Cell Details: Premium Grade A Lithium-Ion Cells
  • Condition: Genuine New
  • Warranty: 12 Monthst

Biomedical Maintenance Directives

To secure the maximum operational lifespan of this lithium-ion module and ensure constant emergency readiness, clinical engineering technicians should implement the following protocols:

  • Continuous Float Charging: Defibrillators are emergency devices. When the Efficia DFM100 is stationed on a crash cart or not in active clinical use, it must remain continuously plugged into a verified AC power source to maintain the battery at a 100% state of charge.

  • Capacity Calibration: Upon initial installation, connect the device to AC power and allow the new battery to reach full capacity before deploying the defibrillator into active patient care.

  • Proactive Replacement Intervals: Despite showing adequate charge levels on the device display, the internal chemical impedance of defibrillator batteries degrades over time due to the extreme nature of their potential discharge cycles. Adhere strictly to the preventative maintenance (PM) replacement timeline outlined in your Philips service manual to avoid unexpected cell collapse during an emergency.

Why Choose This Philips Defibrillator Battery?

The genuine REF 989803206461 battery is designed to deliver consistent power performance and dependable reliability for compatible Philips equipment. Using high-quality lithium-ion cells, this battery provides stable energy output, efficient charging performance, and extended operational life.

Compared with lower-quality aftermarket alternatives, this OEM-quality replacement battery offers better compatibility, enhanced safety protection, and long-term durability, making it a smart investment for maintaining equipment readiness and dependable performance.

Battery Capacity 79.2Wh/5.4Ah
Voltage 14.68V
Model No 989803206461
Warranty 12 Months
🔒 Secure Payment
🚚 International Shipping
🛡 12-Month Warranty
📩 Responsive Support

🔋 Lithium-Ion Battery Conditioning

For optimal electrochemical performance, new lithium-ion batteries should undergo 2–3 complete charge and discharge cycles before reaching full capacity.

This stabilization phase allows the internal cell chemistry to achieve balanced ion distribution, ensuring maximum runtime, stable voltage output, and extended cycle life.

After this initial conditioning period, no further full discharge cycles are required.

✅ Quality Issue – Free Return & Replacement

🛡 Premium Warranty Protection

  • 12-Month Limited Manufacturer Warranty
  • Up to 30-Day Return Guarantee (Policy Based)
  • Replacement for defective or misrepresented items
  • Dedicated customer service response within 24 hours

View Full Warranty Policy →

🚚 Professional Shipping Standards

  • Orders placed Monday–Friday are processed within 1–2 business days. Orders placed on weekends are processed the following Monday.
  • Tracking information appears in your order within 1–2 business days after dispatch.
  • Transit time varies by region and logistics carrier
  • Please verify your shipping address before order confirmation
  • Address changes are not possible once shipment is dispatched

Shipping Policy Details →

📌 Product-Specific Notice

US Shipping: USPS. (Normally 2-15 Business Days)

📩 Customer Care Commitment

We are committed to delivering professional-grade battery solutions and responsive after-sales service. If you experience any issues, please contact our support team before leaving feedback.

Contact Customer Support →

⚕ Safety & Compatibility Notice — Medical Device Battery

This is a replacement battery for the compatible medical device model(s) listed above. It is not a finished medical device. The following guidelines apply:

Who should install Qualified biomedical technicians or authorized service personnel following the device manufacturer's service manual. AED/defibrillator batteries must comply with your facility's maintenance protocol.
After installation Perform a full device self-test per the manufacturer's guidelines. Record the replacement date and result in the device maintenance log.
Emergency use In a medical emergency, always contact local emergency services (911 in the US). This product does not replace emergency response services.
Liability Accessories-Mall supplies replacement batteries for maintenance purposes. We are not liable for outcomes resulting from improper installation or failure to perform post-installation device testing.

Not sure this battery fits? Send us your device model number — we'll confirm before you order.

CC

Cao Chuanping

Power Systems Consultant · 8+ years in replacement battery sourcing & evaluation · View profile →

Disclaimer:
All batteries sold on accessories-mall.com are replacement parts. accessories-mall.com doesn't affiliate with any of the original manufacturers. Any registered trademarks or model names listed above are identified as purposes of showing compatibility only.